ABN-182 User’s Guide
8
3.3 Programming Guide
Following is API description.
1 dev_found
Function name
dev_found
Description
To find the NIC device
Format:
int dev_found(unsigned char prod_num) //v1.04
Input: prod_num
1-1. PROD_ABN182: bypass card of abn182
Return:
0: device was found successfully
-1:can not find device.
2. set_to_normal
Function name
set_to_normal
Description
Set Ethernet segment to normal mode
Format:
int set_to_normal (unsigned char seg, unsigned char proc_dev) //v1.04
Input:
1. seg:It assign which card in structure of card type to do set to normal function.
2. proc_dev:
2-1. PROD_ABN182: bypass card of abn182
Return: 0: return ok.
-1:return fail.